Single-seat control valve suitable for heavy duty service with high differential pressure where flashing or cavitation may occur.
- Compact, high performance, and prevents erosion
- Large Cv value and rangeability
- High vibration resistance and flow shutoff performance (compliant with IEC and JIS standards)
- Compliant with IEC 61508 functional safety standards
Structural drawing | Image
![]() |
---|---|
Valve type | Top guided single seated control valve |
Model No. | HSC_ _ _ |
Size | 1-1/2" to 8" |
Pressure rating | ANSI/JPI 150 to 600 JIS10K to 30K |
End connection | Flanged : RF, FF, RJ Welded : SW, BW |
Body material | Carbon steel Stainless steel |
Trim material | 440CSS 316SS, 316SS with CoCr-A 316LSS, 316LSS with CoCr-A 329J1SS |
Temperature range | −196 to 566°C |
Leakage performance | Class IV, IV-S1, V, VI |
Cv range | 4 to 310 |
Range ability | 50:1 (option 75:1) |
Application | General-use process for petrochemical and chemical plant flushing service |
Option | Bellow seal bonnet, steam jacket Low emission gland packing |