Cage Valves, Double Seated Valves

Cage type double seated control valve Model VDC_ _ _

Model No.
VDC_ _ _
VDC

Cage type double seated control valve for a wide range of applications with pressure rating up to ANSI2500.

  • Vibration and wear resistant construction with the plug held directly in the cage
  • Top-entry structure that is easy to disassemble and can be inspected and maintained in a short time
  • SIL3 Capable - Certified by exida Corporation
Structural drawing
Image
vdc
Image
high_vdc
Valve typeCage type double seated control valveHigh pressure service cage type double seated control vavles
Model No.VDC_ _ _VDC_ _ _
Size5", 10", 12"5", 10", 12"
Pressure ratingANSI/JPI 150 to 600
JIS10K to 40K
ANSI/JPI 900 to 2500
JIS63K
End connectionFlanged : RF, FF, RJFlanged : RF, RJ
Welded : SW, BW
Body materialCarbon steel
Stainless steel
Carbon steel
Stainless steel
Trim materialSCS24
SCS14A with CoCr-A or Atomloy treatment
SCS16A, SCS16A with CoCr-A
SCS24
SCS14A, SCS14A with CoCr-A,
SCS14A with Atomloy treatment
SCS16A, SCS16A with CoCr-A
Temperature range-195 to 600°C0 to 520°C
Leakage performanceClass II, III, VIClass II, III
Cv range99 to 1440Class 1500 or less : 83 to 1180
Class 2500 : 56 to 820
Range ability30:1 (option 50:1)30:1 (option 50:1)
ApplicationGeneral-use process for petrochemical and chemical plantHigh temperature and high pressure steam of boiler and turbine unit for power plant and private power generation
OptionBellow seal bonnet, steam jacket-

A wide range of material specifications

Products can be provided by using different materials for valve stems - e.g., carbon steel is generally used with water, steam, and fuel oil; and high corrosion resistant stainless steel that is essential for controlling corrosive fluids.

Corresponding to service

The excellent anti-cavitation performance of these cage valves plays an essential role in controlling fluids at high temperatures and under high differential pressures. Optional specifications can be applied to reduce aerodynamic noise produced by steam and gas.

Excellent seat leakage performance

Metal sheet tight shut (class II, III) and soft sheet tight shut (class VI) are available.

Excellent external leakage prevention performance

A bellows seal can be added to valve stems. Increasingly sought-after specifications for gland packings can be applied to comply with fugitive emission regulations of volatile organic compounds.

High control performance

High control performance is achieved by a combination of wide rangeability and a smart valve positioner.
The original internal valve structure adopted by azbil essentially eliminated the shortcomings of conventional double-seated control valves that suffered from reversal of fluid reaction force, thereby achieving stable control.

Inquiries about field instruments and control valves