Single Seated Valves

Micro-flow control valve Model VSM_ _ _

Model No.
VSM_ _ _
VSM

This is a highly accurate control valve with a valve size of 1B or less that excels in minute flow control. Handles minute flow rates of CNG, hydrogen, etc.

  • Flange connection valve sizes ½B, ¾B, and 1B.
  • Compatible with screw-in valve sizes: Rc ¼ Rc ½, ¼ NPT, and ½ NPT
  • Pressure rating supports up to JIS63K and ANSI2500
Structural drawing
Image
VSM
Valve typeMicro-flow control valve
Model No.VSM_ _ _
SizeThreaded : NPT (Rc) 1/4", 1/2" Flanged : 1/2", 3/4", 1"
Pressure ratingANSI/JPI 150 to 2500
JIS10K to 63K
End connectionThreaded : Rc, NPT
Flanged : RF, RJ
Body materialStainless steel
Trim materialSolid CoCr-A
Temperature range-30 to 400°C
Leakage performanceClass IV
Cv range0.001 to 0.63
Range ability20:1 to 30:1
ApplicationNeedle type plug
Addition process of chemical and perfume
Option-

A wide range of available materials

Products can be provided to meet a variety of body material specifications, such as: carbon steel, which is generally used with water, steam, and fuel oil; highly corrosion resistant stainless steel, which is essential for controlling corrosive fluids; and resin.

Excellent seat leakage performance

Metal seat tight shutoff (class V) and soft seat tight shutoff (class VI) are available.

High control performance

High control performance is achieved by a combination of wide rangeability and a smart valve positioner.

Inquiries about field instruments and control valves