Single Seated Valves

Model VST_ _ _ Single-Seated Control Valve

Model No.
VST_ _ _
VST

A single-seated control valve with sturdy construction and a valve structure suitable for slurry fluids.

  • Flange rating: JIS10K to 30K, ANSI/JPI 150 to 600, corresponding to valve nominal sizes 5B, 10B, and 12B.
  • Flange rating: JIS63K, ANSI/JPI 900 to 2500, corresponding to valve nominal sizes 4B, 5B, and 6B.
  • The guide section has sufficient sliding area, and has a structure that is robust and easy to disassemble and inspect.
Structural drawing
Image
VST_1
Image
VST_2
Valve typeTop guided single seated control valveHigh-pressure service top guided single seated control valve
Model No.VST_ _ _VST_ _ _
Size5", 10", 12"4", 5", 6"
Pressure ratingANSI/JPI 150 to 600
JIS10K to 30K
ANSI/JPI 900 to 2500
JIS63K
End connectionFlanged : RF, FF, RJ
Welded : SW, BW
Flanged : RF, RJ
Welded : SW, BW
Body materialCarbon steel
Stainless steel
Carbon steel
Trim material440CSS
316SS, 316SS with CoCr-A
316LSS, 316LSS with CoCr-A
440CSS
SUS304 with CoCr-A
Temperature range-101 to 520°C0 to 520°C
Leakage performanceClass IV, IV-S1, V, VIClass IV
Cv range99 to 1440class 1500 or less : 56 to 315
class 2500 : 39 to 210
Range ability30:130:1
ApplicationGeneral-use process for petrochemical and chemical plantHigh temperature and high pressure steam of boiler and turbine unit for power plant and private power generation
Option--

A wide range of available materials

Products can be provided to meet a variety of body material specifications, such as: carbon steel, which is generally used with water, steam, and fuel oil; highly corrosion resistant stainless steel, which is essential for controlling corrosive fluids; and resin.

Response to severe service

For severe service such as high temperatures and high differential pressures, cage-type single-seat valves with excellent cavitation resistance are available.

Excellent seat leakage performance

Metal seat tight shutoff (class IV) and soft seat tight shutoff (class VI) are available.

Inquiries about field instruments and control valves