Angle Valves

High pressure service angle control valve Model HAH_ _ _

Model No.
HAH_ _ _
HAH

An angle control valve for high-pressure service with ANSI2500 body rating

  • High-voltage service up to ANSI2500
  • Valve plug and seat ring of hard alloy steel to prevent abrasion by high-pressure fluid
Structural drawing
Image
HAH
Valve typeHigh pressure service angle control valve
Model No.HAH_ _ _ 
Size3/4" to 1-1/2"
Pressure ratingANSI 2500
End connectionFlanged : RF, RJ
Body materialForged carbon steel
Stainless steel
Trim material440CSS
316SS with CoCr-A
Temperature range0 to 425°C
Leakage performanceClass IV
Cv range0.33 to 9
Range ability30:1 (option 50:1)
ApplicationAbrasion service of high temperature
and high pressure
Option-

Angle valves are structured so that the center lines of the entrance and exit of the fluid intersect perpendicularly. In general, the horizontal line is the entrance and the vertical line is the exit.
This structure allows the fluids commonly known as slurry (i.e. viscous fluids and fluids including solid bodies) to pass more easily through the valve, making it suitable for controlling them. Additionally, it prevents the valve from being damaged due to fluid cavitation and flashing, making it suitable for fluids with these conditions.
This valve type is mainly adopted to solve problems that are difficult to address with general-purpose valves. Therefore, we can apply various materials (e.g., ceramic and cemented carbide) to the trim parts and its peripheral parts in order to handle special needs.

Inquiries about field instruments and control valves