Angle Valves

Super-high pressue angle control valve Model VAU_ _ _

Model No.
VAU_ _ _
VAU_690_380.jpg

A super-high-pressure angle control valve with a body rating of 343 MPa

  • Control of super-high pressure and minute flow rate in high-pressure polyethylene equipment, etc.
  • Valve body of forged stainless steel
  • Robust, compact, highly accurate actuator is made of high tensile strength aluminum alloy
Structural drawing
Image
VAU
Valve typeSuper-high pressue angle control valve
Model No.VAU_ _ _
SizePlease contact us
Pressure ratingMax. pressure : 343MPa
End connectionPlease contact us
Body materialStainless steel
Trim materialSolid CoCr-A
Temperature range0 to 100°C
Leakage performanceClass IV
Cv range0.003 to 0.006 (ON-OFF 0.062)
Range ability-
ApplicationHard slurry service
Option-

Angle valves are structured so that the center lines of the entrance and exit of the fluid intersect perpendicularly. In general, the horizontal line is the entrance and the vertical line is the exit.
This structure allows the fluids commonly known as slurry (i.e. viscous fluids and fluids including solid bodies) to pass more easily through the valve, making it suitable for controlling them. Additionally, it prevents the valve from being damaged due to fluid cavitation and flashing, making it suitable for fluids with these conditions.
This valve type is mainly adopted to solve problems that are difficult to address with general-purpose valves. Therefore, we can apply various materials (e.g., ceramic and cemented carbide) to the trim parts and its peripheral parts in order to handle special needs.