Sanitary Differential Pressure/Pressure Transmitters (Model JTC9_ _ _/JTE9_ _ _) with built-in microprocessors meet sanitary standards while maintaining high reproducibility and precise accuracy. Connection to pipes is by ISO-compliant sanitary-use clamps for easy attachment, removal, and maintenance.
Model | JTC929S | JTC940S | JTE929S | JTE930S |
---|---|---|---|---|
Measurement span | 2.5 to 100 kPa | 70 to 3500 kPa | 2.5 to 100 kPa | 35 to 700 kPa |
Setting range | -100 to 100 kPa | -100 to 3500 kPa | -100 to 100 kPa | -100 to 700 kPa |
Reference accuracy(Varies by material and measurement span) | ±0.3% | ±0.2% | ±0.3% | ±0.2% |
Fill fluid | Propylenglycol (a food additive) | |||
Waterproof and dust-proof construction | IEC IP66/IP67 | |||
Explosion-proof construction | TIIS explosion proof (Exd IICT4) | |||
Range of operating temperatures for liquid part(Varies with pressure) | -10 to 121°C Steam wash time: 150 °C for 60 min | |||
Range of operating pressures for liquid part(Varies with temperature) | from 10 kPa abs | |||
Wetted material | SUS316 (diaphragm SUS316L) | |||
Power | 17.9 to 45 V DC | |||
Output signal | 4 to 20 mA DC (SFN communication) 4 to 20 mA DC (HART® communication) | |||
Process connections | ISO 100 (4S) clamps | ISO 50 (2S), 80 (3S), 100 (4S) clamp connections ISO 50 (2S) Domend cap nut |