Differential Pressure Transmitter / Pressure Transmitters Advanced Transmitter Model GTX_ _ _

Absolute Pressure Transmitters

Model No.
GTX30A, GTX60A
GTX-GA-L

This is a microprocessor-based smart transmitter with excellent stability. It can measure the absolute pressure of gases, liquids, steam, etc.

  • Safe instrumentation: IEC 61508-compliant and SIL2-certified
  • Excellent usability: zero/span adjustment without opening the cover
  • Various functions: send alarm information by contact output (optional)

Advanced Transmitter Absolute Pressure Transmitters (Model GTX_ _A) are used to measure the absolute pressure of gases, liquids, and steam, as well as to monitor tank pressure. With their extremely wide measurement range (GTX60A: 35 to 3500 kPa, a rangeability of 1:100), they help to cut costs by reducing the number of spare units required.

ModelGTX30AGTX60A
Measurement span4~104 kPa35~3500 kPa
Setting range0~104 kPa abs0~3500 kPa abs
Reference accuracy(Varies by material and measurement span)±0.15%±0.15%
Fill fluidSilicone oil (general purpose models), fluorine oil (oxygen and chlorine models)
Waterproof and dust-proof constructionIEC IP66/IP67
Explosion-proof constructionTIIS flameproof (Exd IICT4)
KOSHA flameproof
FM explosion proof, intrinsic safe and Nonincendive
ATEX/NEPSI/IECEx flameproof, intrinsic safe and Type n
Wetted materialSUS316 (diaphragm SUS316L), Alloy C-276, Tantalum
Power17.9~42V DC
Output signal4 to 20 mA DC (SFN communication)
4 to 20 mA DC (HART® communication)
Safety certificationSafety Integrity Level (SIL) 2 certification

Inquiries about field instruments and control valves