Field Communication Software CommStaff Model CFS100 allows the user to configure and adjust smart field devices using a PC. In addition to supporting Azbil Corporation's proprietary SFN communication protocol for smart field devices, with a change of the communication interface, CommStaff supports the HART communication protocol. Parameter settings can be saved to simplify field device management.
Supports HART and Azbil Corporation's SFN communication protocols.
With the use of Azbil's communication interface Smart HART modem Model AZ-1SHM, CommStaff now supports both HART and Azbil Corporation's SFN communication protocol.
Ease-of-use increases field work efficiency
The ease-of-use of the five-point check function increases efficiency during loop checks.
Easy management of configured parameters
- Parameter settings can be saved by Tag No.
- As needed, parameter settings can be exported as either a CSV file (text file) or as a PDF.
Supported models
| Supported models | Communication Protocol | ||
|---|---|---|---|
| SFN | DE | HART | |
| Smart Transmitter | Image
| Image
| Image
|
| Advanced Transmitter Model GTX / Pressure Transmitter Model JT_ _ _ _ _ | Image
| Image
| Image
|
| Smart Multivariable Flow Transmitter Model JTD720A | Image
| Image
| Not supported |
| Smart Pressure Transmitters Model PTG_ _ _ | Image
| Image
| Image
|
| Advanced Temperature Transmitters Model ATT082 | Not supported | Not supported | Image
|
| Advanced Temperature Transmitter Model ATT_ _ _ (In case of SFN/DE communication, can apply for software version 3.5 or later.) | Ver 3.5 or later | Ver 3.5 or later | Image
|
| Steam Flow Meter Model MVC3_ _ | Image
| Not supported | Not supported |
| Displacement type Level Transmitter Model SLX_ _ _ | Image
| Not supported | Not supported |
| Immersion Type Liquid Level Transmitter Model JTL32_/JTL33_ | Image
| Not supported | Not supported |
| Smart ESD Device 700 Series Model AVP 77_/78_79_ for Safety Instrumented Systems(SIS) | Not supported | Not supported | Image
|
| Smart Valve Positioner 700 series Model AVP70_ | Not supported | Not supported | Image
|
| Smart Valve Positioner 200/300 Series Model AVP20_/30_ (In case of HART® communication, can apply for software version 3.9 or later.) | Image
| Image
| Ver 3.9 or later |
| Smart Valve Positioner for Rotary Valve Model SVX10_ (In case of HART® communication, can apply for software version 4.A or later.) | Image
| Image
| Ver 4.A or later |
| Electromagnetic Flowmeter Converter MagneW™ FLEX+ Model MGG_ _ _ (In case of SFN/DE communication, can apply for software version 6.0 or later. In case of HART® communication, can apply for software version 5.0 or later.) | Ver 6.0 or later | Ver 6.0 or later | Ver 5.0 or later |
| Two-wire Electromagnetic Flowmeter MagneW™ Neo PLUS / Two-wire PLUS+ Model MTG_ _ _ (In case of SFN/DE communication, can apply for software version 5.0 or later.) | Ver 5.0 or later | Ver 5.0 or later | Image
|
| Natural Gas Calorimeter GasCVD Model CVM400 | Not supported | Not supported | Image
|
| Multivariable Vortex Flow Meters Models AX22_ _/23_ _ (In case of HART® communication, can apply for software ver. 78.02 or later.) | Not supported | Not supported | Ver 78.02 or later |
PC system
| Software | OS | Windows 10 Pro , Windows 11 Pro (32-bit or 64-bit Japanese or English edition) |
| Hardware | HDD | 500 MB mininum |
| USB | One, USB 2.0 or Higher | |
| CD-ROM | Needed for installation only |