![JTF-L](/jp/files/default/2023-03/25_JTF-L_690_380.jpg)
Flange-Mounted Differential Pressure Transmitters (Model JTC9_ _ _) can be attached to a tank-side flange to take measurements of fluid level, specific gravity, etc. We offer an extensive lineup ranging from small bore 40 mm models to 100 mm protruding flange models.
Model | JTC929_ | JTC940_ |
---|---|---|
Measurement span | 2.5 to 100 kPa | 70 to 3500 kPa |
Setting range | -100 to 100 kPa | -100 to 3500 kPa |
Reference accuracy(Varies by material and measurement span) | ±0.15% | ±0.1% |
Fill fluid | Silicone oil (general purpose models), fluorine oil (oxygen and chlorine models) | |
Waterproof and dust-proof construction | IEC IP66/IP67 | |
Explosion-proof construction | TIIS explosion proof (Exd IICT4) | |
Range of operating temperatures for liquid part(Varies with pressure) | Silicone oil: -40 to 110°C Fluorine oil: -10 to 75°C | |
Range of operating pressures for liquid part(Varies with temperature) | Silicone oil: from 2 kPa abs Fluorine oil: from 54 kPa abs | |
Wetted material | SUS316 (diaphragm SUS316L), Alloy C-276 , Tantalum | |
Power | 17.9 to 45 V DC | |
Output signal | 4 to 20 mA DC (SFN communication) 4 to 20 mA DC (HART® communication) | |
Process connections | Rc 1/2 or 1/2 NPT internal thread or open to air | |
Flange bore | Flush models: 80 mm, 50 mm, 40 mm. Protruding models: 100 mm, 80 mm, 50 mm |