This is a microprocessor-based smart transmitter with excellent stability. The remote seal pressure transmitter can measure the absolute pressure in reaction vessels, distillation equipment, etc., in which vacuum pressure range is reached and the temperature or pressure is very high.
- Safe instrumentation: IEC 61508-compliant and SIL2-certified
- Excellent usability: zero/span adjustment without opening the cover
- Various functions: send alarm information by contact output (optional)
Advanced Transmitter Remote-sealed Absolute Pressure Transmitters (Model GTX_ _S) are well-suited for tasks such as measuring the absolute pressure of jacketed reactor distillation equipment in which the vacuum pressure range is reached and temperature or pressure are very high.
| Model | GTX30S | GTX60S |
|---|---|---|
| Measurement span | 4~104 kPa | 35~3500 kPa |
| Setting range | 0~104 kPa abs | 0~3500 kPa abs |
| Reference accuracy(Varies by material and measurement span) | ±0.25% | ±0.25% |
| Fill fluid | Silicone oil (for high temperature and high temperature vacuum models) | |
| Waterproof and dust-proof construction | IEC IP66/IP67 | |
| Explosion-proof construction | TIIS flameproof (Exd IICT4) KOSHA flameproof FM explosion proof, intrinsic safe and Nonincendive ATEX/NEPSI/IECEx flameproof, intrinsic safe and Type n | |
| Range of operating temperatures of liquid part(Varies with pressure) | High temperature vacuum models: -5 to 280 °C High temperature high vacuum models: 10 to 300 °C | |
| Range of operating pressures for liquid part(Varies with temperature) | 0.13 kP a abs~ | |
| Wetted material | SUS316 (diaphragm SUS316L) | |
| Power | 17.9~42V DC | |
| Output signal | 4 to 20 mA DC (SFN communication) 4 to 20 mA DC (HART® communication) | |
| Flange bore | Flush models: 80 mm. Protruding models: 100 mm | |
| Safety certification | Safety Integrity Level (SIL) 2 certification | |