Differential Pressure Transmitter / Pressure Transmitters Advanced Transmitter Model GTX_ _ _

Remote-sealed Differential Pressure Transmitters

Model No.
GTX35R, GTX40R
GTX-R-L_

This is a microprocessor-based smart transmitter with excellent stability. It is suitable for measuring the differential pressure (flow rate, liquid level, etc.) of fluids that are highly corrosive or condensable, or fluids with deposited metal.

  • Safe instrumentation: IEC 61508-compliant and SIL2-certified
  • Excellent usability: zero/span adjustment without opening the cover
  • Various functions: send alarm by contact output (optional)

Advanced Transmitter Remote-sealed Differential Pressure Transmitters Transmitters (Model GTX_ _R) are used to measure differential pressure (flow rate, fluid level, etc.) of high-temperature or highly corrosive, condensable fluids. We offer an extensive lineup including small bore flange models starting at 40 mm and models for high temperature (including high temperature high vacuum) applications.

ModelGTX35RGTX40R
Measurement span2.5~100 kPa35~700 kPa
Setting range-100~100 kPa-100~700 kPa
Reference accuracy(Varies by material and measurement span)±0.2%±0.2%
Fill fluidSilicone oil (for the following models: general purpose, high temperature, high temperature vacuum, and high temperature high vacuum)
Fluorine oil (oxygen and chlorine models)
Waterproof and dust-proof constructionIEC IP66/IP67
Explosion-proof constructionTIIS flameproof (Exd IICT4)
KOSHA flameproof
FM explosion proof, intrinsic safe and Nonincendive
ATEX/NEPSI/IECEx flameproof, intrinsic safe and Type n
Range of operating temperatures for liquid part(Varies with pressure)
Range of operating pressures for liquid part(Varies with temperature)
Silicone oil: -40 to 280 °C (varies with fill fluid)
Fluorine oil: -10 to 120 °C
Silicone oil for general purpose and high temperature models: from 2 kPa abs
High temperature vacuum and high temperature high vacuum models: from 0.13 kPa abs
Fluorine oil: from 53 kPa abs
Wetted materialSUS316 (diaphragm SUS316L), Hastelloy C, Tantalum
Power17.9~42V DC
Output signal4 to 20 mA DC (SFN communication)
4 to 20 mA DC (HART® communication)
Flange boreFlush models: 80 mm, 50 mm, 40 mm. Protruding models: 100 mm, 80 mm, 50 mm
Safety certificationSafety Integrity Level (SIL) 2 certification

Inquiries about field instruments and control valves