This is a microprocessor-based smart transmitter with excellent stability. It can measure the flow rate and pressure of gases, liquids, and steam, as well as liquid levels.
- Safe instrumentation: IEC 61508-compliant and SIL2-certified
- Excellent long-term stability: zero point drift of only ±0.1 % over 10 years
- High-speed response within 100 ms for turbines and other applications that require fast response
Product Video
Advanced Transmitter Differential Pressure Transmitters (Model GTX_ _D) are used to measure the flow rate of gases, liquids, and steam, to measure tank fluid levels, etc. They provide high accuracy of ±0.04 % together with long-term stability (zero drift of only ±0.1 % over 10 years), greatly reducing calibration work after installation.
Other models measure minute pressure differences as low as 0.1 kPa, or withstand pressures as high as 42 MPa.
Differential Pressure Transmitters
| Model | GTX15D | GTX30D/31D | GTX41D | GTX71D |
|---|---|---|---|---|
| Measurement span | 0.1~2 kPa | 0.5~100 kPa | 35~700 kPa | 0.25~14 MPa |
| Setting range | -1~1 kPa | -100~100 kPa | -100~700 kPa | -0.1~14 MPa |
| Reference accuracy(Varies by material and measurement span) | ±0.3% | ±0.04% | ±0.1% | ±0.15% |
| Fill fluid | Silicone oil (general purpose models), fluorine oil (oxygen and chlorine models) | |||
| Waterproof and dust-proof construction | IEC IP66/IP67 | |||
| Explosion-proof construction | TIIS flameproof (Exd IICT4) KOSHA flameproof FM explosion proof, intrinsic safe and Nonincendive ATEX/NEPSI/IECEx flameproof, intrinsic safe and Type n | |||
| Wetted material | SUS316 (diaphragm SUS316L) | SUS316 (diaphragm SUS316L), Alloy C-276, Tantalum | ||
| Power | 17.9~42V DC | |||
| Output signal | 4 to 20 mA DC (SFN communication) 4 to 20 mA DC (HART® communication) | |||
| Safety certification | Safety Integrity Level (SIL) 2 certification | |||
High-Pressure Resistant Differential Pressure Transmitter
| Model | GTX32D | GTX42D | GTX72D |
|---|---|---|---|
| Measurement span | 0.5~100 kPa | 35~700 kPa | 0.25~14 MPa |
| Setting range | -100~100 kPa | -100~700 kPa | -0.1~14 MPa |
| Reference accuracy(Varies by material and measurement span) | ±0.1% | ±0.1% | ±0.15% |
| Fill fluid | Silicone oil (general purpose models), fluorine oil (oxygen and chlorine models) | ||
| Waterproof and dust-proof construction | IEC IP66/IP67 | ||
| Explosion-proof construction | TIIS flameproof (Exd IICT4) KOSHA flameproof FM explosion proof, intrinsic safe and Nonincendive ATEX/NEPSI/IECEx flameproof, intrinsic safe and Type n | ||
| Wetted material | SUS316 (diaphragm SUS316L) | ||
| Power | 17.9~42V DC | ||
| Output signal | 4 to 20 mA DC (SFN communication) 4 to 20 mA DC (HART® communication) | ||
| Safety certification | Safety Integrity Level (SIL) 2 certification | ||