You can download the free installation file for the SLP-C1F.
Please check the privacy policy at the bottom of this page, then fill in the customer information form to register and download the file.
File Information
| Device | Model C1M/C1A/C2/C3 |
|---|---|
| Software | Model SLP-C1F |
| Version | 3.2.2 (Japanese/English/Chinese) |
| Size | Approx. 31.1 MB |
The following text is machine translated. Please be aware of this in advance.
*****************************************************************************
Form SLP-C1F Change Log
Version: 3.2.2 (August 2024)
- New Features
- The following latest F/W corresponding to C1M/C1A/C2/C3 can be updated.
C1M: Ver. 1.0.3
C1A: Ver. 1.0.5
- The following latest F/W corresponding to C1M/C1A/C2/C3 can be updated.
- Functional improvement
- When the PV range type and temperature unit are changed, the decimal point position, etc. are updated in conjunction with the zone related set values.
- Bug Fixes (None)
Version: 3.1.3 (July 2024)
- New Features
- Supported Fahrenheit model numbers. (Overseas specifications only)
- Added the ability to copy & paste pattern information across banks.
- Added support for C2/C3.
- Added support for parameter reading functions for C25/26/35/36.
- Added support for F/W update function of the regulator itself.
- Functional Improvements
- Displayed the communication address in the status bar while displaying the bank related to pattern operation.
- Changed the delimiter for the trend monitor log save function to ";" (semicolon) when used in countries with numeric separators as "," (comma).
- Made it possible to use X/Y devices of the MELSEC iQ-F series in octal notation.
- Changed the USB loader cable driver to one officially supported by Win11.
- Improved the operability of the model number setting window.
- Improved to output all bank information of pattern information when outputting CSV.
- Improved the display layout and other aspects.
- Bug Fixes
- Addressed abnormalities that occur during zoom in, zoom out, and horizontal scroll operations on the trend monitor screen.
- Fixed an issue where settings written with SLP-C1F Ver.1 could not be restored with SLP-C1F Ver.2 when specifying Omron PLC in PLC link.
- Fixed minor issues.
Version: 2.3.0 (December 2023)
- New Features (None)
- Functional Improvements
- During the execution of the adjustment value restore function, improved to prevent initialization of the adjustment value area under specific conditions, and to display a warning if an issue occurs.
- Modified to reset the main unit when the adjustment value restore is executed.
- Bug Fixes (None)
Version: 2.2.0 (June 2023)
- New Features (None)
- Functional Improvements
- Modified the list of configurable devices for Mitsubishi Electric's MELSEC F series. When connecting to the relevant PLC, please reconfigure the devices set with Ver. 2.1.1 or earlier using Ver. 2.2.0 or later.
- Bug Fixes
- Fixed an issue where device display may be corrupted in PLC link.
- Fixed minor issues.
Version: 2.1.1 (April 2023)
- New Features (None)
- Functional Improvements (None)
- Bug Fixes
- Added display of the parameter "Operation Amount Change Limit."
- Fixed an issue where some parameters would have abnormal values when reading settings created with form SLP-C35.
- Fixed minor issues.
Version: 2.0.0 (February 2023)
- New Features
- Added support for form C1A.
- Added a launcher program to launch SLP supporting forms C1M and C1A.
- Functional Improvements
- Changed the method of selecting communication ports on the environment settings screen.
- Enabled direct input of addresses for form C1M in PLC link, and displayed parameter names.
- Split the Mitsubishi PLCs into two categories: Q series and iQ series.
- Added PLC-related monitor values to the numeric monitor. (PLC scan count, PLC scan time, PLC scan time (max), PLC max node count)
- Changed the log save method for trend monitor. Previously saved with trend trigger settings, now always saves logs.
- Changed the extension of the setting file saving parameters from *.c1f to *.c1m.
- Increased the update speed of the numeric monitor information.
- Improved the display layout and other aspects.
- Bug Fixes
- Corrected to properly reflect decimal point information in trend logs.
- Fixed a zero-division error occurring under specific conditions in the PID simulator.
- Fixed minor issues.
Version: 1.4.1 (August 2022)
- New Features (None)
- Functional Improvements (None)
- Bug Fixes
- Fixed an issue where the AT function in PID simulation may not complete.
- Fixed an issue where changing the sampling period in PID simulation would alter the setting range of the PID slider.
- Fixed minor issues.
Version: 1.3.1 (June 2022)
- New Features (Initial release)
- Functional Improvements (None)
- Bug Fixes (None)
*****************************************************************************
Azbil Corporation
*****************************************************************************
- Bug Fixes (None)
Please refer to Smart Loader Package Model SLP-C1F Installation Manual.
Double-click "setup.msi" in the extracted folder to start the installation. When the installation is complete, the message "Completed the SLP-C1F Setup Wizard" will be displayed.