Feld Communication Software

Feld Communication Software Model CFS100

Model No.
CFS100
AVPCFS

Field Communication Software CommStaff Model CFS100 allows the user to configure and adjust smart field devices using a PC. In addition to supporting Azbil Corporation's proprietary SFN communication protocol for smart field devices, with a change of the communication interface, CommStaff supports the HART communication protocol. Parameter settings can be saved to simplify field device management.

Supports HART and Azbil Corporation's SFN communication protocols.

With the use of Azbil's communication interface Smart HART modem Model AZ-1SHM, CommStaff now supports both HART and Azbil Corporation's SFN communication protocol.

Ease-of-use increases field work efficiency

The ease-of-use of the five-point check function increases efficiency during loop checks.

Easy management of configured parameters

  • Parameter settings can be saved by Tag No.
  • As needed, parameter settings can be exported as either a CSV file (text file) or as a PDF.

Supported models

Supported modelsCommunication Protocol
SFNDEHART
Smart Transmitter
Image
check
Image
check
Image
check
Advanced Transmitter Model GTX / Pressure Transmitter Model JT_ _ _ _ _
Image
check
Image
check
Image
check
Smart Multivariable Flow Transmitter Model JTD720A
Image
check
Image
check
Not supported
Smart Pressure Transmitters Model PTG_ _ _
Image
check
Image
check
Image
check
Advanced Temperature Transmitters Model ATT082Not supportedNot supported
Image
check
Advanced Temperature Transmitter Model ATT_ _ _
(In case of SFN/DE communication, can apply for software version 3.5 or later.)
Ver 3.5 or laterVer 3.5 or later
Image
check
Steam Flow Meter Model MVC3_ _
Image
check
Not supportedNot supported
Displacement type Level Transmitter Model SLX_ _ _
Image
check
Not supportedNot supported
Immersion Type Liquid Level Transmitter Model JTL32_/JTL33_
Image
check
Not supportedNot supported
Smart ESD Device 700 Series Model AVP 77_/78_79_ for Safety Instrumented Systems(SIS)Not supportedNot supported
Image
check
Smart Valve Positioner 700 series Model AVP70_Not supportedNot supported
Image
check
Smart Valve Positioner 200/300 Series Model AVP20_/30_
(In case of HART® communication, can apply for software version 3.9 or later.)
Image
check
Image
check
Ver 3.9 or later
Smart Valve Positioner for Rotary Valve Model SVX10_
(In case of HART® communication, can apply for software version 4.A or later.)
Image
check
Image
check
Ver 4.A or later
Electromagnetic Flowmeter Converter MagneW™ FLEX+ Model MGG_ _ _
(In case of SFN/DE communication, can apply for software version 6.0 or later.
In case of HART® communication, can apply for software version 5.0 or later.)
Ver 6.0 or laterVer 6.0 or laterVer 5.0 or later
Two-wire Electromagnetic Flowmeter MagneW™ Neo PLUS / Two-wire PLUS+ Model MTG_ _ _
(In case of SFN/DE communication, can apply for software version 5.0 or later.)
Ver 5.0 or laterVer 5.0 or later
Image
check
Natural Gas Calorimeter GasCVD Model CVM400Not supportedNot supported
Image
check
Multivariable Vortex Flow Meters Models AX22_ _/23_ _
(In case of HART® communication, can apply for software ver. 78.02 or later.)
Not supportedNot supportedVer 78.02 or later

PC system

SoftwareOSWindows 10 Pro , Windows 11 Pro
(32-bit or 64-bit Japanese or English edition)
HardwareHDD500 MB mininum
USBOne, USB 2.0 or Higher
CD-ROMNeeded for installation only

Inquiries about field instruments and control valves