Differential Pressure Transmitter / Pressure Transmitters Advanced Transmitter Model GTX_ _ _

Remote-Sealed Gauge Pressure Transmitters

Model No.
GTX35U, GTX60U, GTX71U, GTX82U
GTX-U-L

This is a microprocessor-based smart transmitter with excellent stability. It is suitable for measuring the pressure of fluids that are highly corrosive or condensable, or fluids with deposited metal.

  • Safe instrumentation: IEC 61508-compliant and SIL2-certified
  • Excellent usability: zero/span adjustment without opening the cover
  • Various functions: send alarm information by contact output (optional)

Advanced Transmitter Remote-sealed Gauge Pressure Transmitters (Model GTX_ _U) are used to measure pressure (pressure, fluid level, etc.) of high-temperature or highly corrosive, condensable fluids. We offer an extensive lineup, including small bore flange models starting at 40 mm and models for high temperature (including high temperature high vacuum) applications.

ModelGTX35UGTX60UGTX71UGTX82U
Measurement span2.5~100 kPa35~3500 kPa0.7~10 MPa0.7~42 MPa
Setting range-100~100 kPa-100~3500 kPa-0.1~10 MPa-0.1~42 MPa
Reference accuracy(Varies by material and measurement span)±0.2%±0.2%±0.2%±0.2%
Fill fluidSilicone oil(for general purpose and high temperature models)Silicone oil(for general purpose, high temperature, high temperature vacuum, and high temperature high vacuum models)Silicone oil(oxygen models)
Fluorine oil(oxygen and chlorine models)Fluorine oil(oxygen and chlorine models)Fluorine oil(oxygen models)
Waterproof and dust-proof constructionIEC IP66/IP67
Explosion-proof constructionTIIS flameproof (Exd IICT4)
KOSHA flameproof
FM explosion proof, intrinsic safe and Nonincendive
ATEX/NEPSI/IECEx flameproof, intrinsic safe and Type n
Range of operating temperatures for liquid part(Varies with pressure)Silicone oil: -40 to 280 °C (varies with fill fluid)
Fluorine oil: -10 to 120 °C
Silicone oil:-40 to 180 °C
Fluorine oil:-10 to 120 °C
Range of operating pressures for liquid part(Varies with temperature)Silicone oil General purpose and high temperature models: from 2 kPa absSilicone oil General purpose and high temperature models: from 2 kPa abs
High temperature vacuum and high temperature high vacuum models: 0.13 kPa abs
Silicone oil: from 2 kPa abs
Fluorine oil: from 54 kPa absFluorine oil: from 54 kPa absFluorine oil: from 54 kPa abs
Wetted materialSUS316 (diaphragm SUS316L), Alloy C-276, TantalumSUS316 (diaphragm SUS316L)
Power17.9~42V DC
Output signal4 to 20 mA DC (SFN communication), 4 to 20 mA DC (HART®communication)
Process connectionsFlush type: 80 mmFlush type: 80 mm, 50 mm, 40 mmButton diaphragm type
Protruding type: 100 mmProtruding type: 100 mm, 80 mm, 50 mm2B wafer type
2B wafer type2B wafer type 
Safety certificationSafety Integrity Level (SIL) 2 certification

Product inquiry