Differential Pressure Transmitter / Pressure Transmitters Advanced Transmitter Model JT_9_ _S/W

Remote-sealed Differential Pressure Transmitters Model JTE9_ _ _

Model No.
JTE929S, JTE929W, JTE930S, JTE930W
JTE-L

Remote-sealed Differential Pressure Transmitters (Model JTE9_ _ _) are used to measure the differential pressure (flow rate, fluid level, etc.) of very hot as well as highly corrosive and condensable fluids. We offer an extensive lineup, including small bore flange models starting at 40 mm and models for high temperature (including high temperature high vacuum) applications.

ModelJTE929_JTE930_
Measurement span2.5 to 100 kPa35 to 700 kPa
Setting range-100 to 100 kPa-100 to 700 kPa
Reference accuracy(Varies by material and measurement span)±0.15%±0.15%
Fill fluidSilicone oil (for the following models: general purpose, high temperature, high temperature vacuum, and high temperature high vacuum)
Fluorine oil (oxygen and chlorine models)
Waterproof and dust-proof constructionIEC IP66/IP67
Explosion-proof constructionTIIS explosion proof (Exd IICT4)
Range of operating temperatures for liquid part(Varies with pressure)Silicone oil: -40 to 280 °C (varies with fill fluid)
Fluorine oil: -10 to 120 °C
Range of operating pressures for liquid part(Varies with temperature)Silicone oil for general purpose and high temperature models: from 2 kPa abs
High temperature vacuum and high temperature high vacuum models: from 0.13 kPa abs
Fluorine oil: from 54 kPa abs
Wetted materialSUS316 (diaphragm SUS316L), Alloy C-276, Tantalum
Power17.9 to 45 V DC
Output signal4 to 20 mA DC (SFN communication)
4 to 20 mA DC (HART® communication)
Flange boreFlush models: 80 mm, 50 mm, 40 mm. Protruding models: 100 mm, 80 mm, 50 mm

Product inquiry