Differential Pressure Transmitter / Pressure Transmitters Advanced Transmitter Model JT_9_ _S/W

Flange-Mounted Differential Pressure Transmitters Model JTC9_ _ _

Model No.
JTC929S, JTC929W, JTC940S, JTC940W
JTF-L

Flange-Mounted Differential Pressure Transmitters (Model JTC9_ _ _) can be attached to a tank-side flange to take measurements of fluid level, specific gravity, etc. We offer an extensive lineup ranging from small bore 40 mm models to 100 mm protruding flange models.

ModelJTC929_JTC940_
Measurement span2.5 to 100 kPa70 to 3500 kPa
Setting range-100 to 100 kPa-100 to 3500 kPa
Reference accuracy(Varies by material and measurement span)±0.15%±0.1%
Fill fluidSilicone oil (general purpose models),
fluorine oil (oxygen and chlorine models)
Waterproof and dust-proof constructionIEC IP66/IP67
Explosion-proof constructionTIIS explosion proof (Exd IICT4)
Range of operating temperatures for liquid part(Varies with pressure)Silicone oil: -40 to 110°C
Fluorine oil: -10 to 75°C
Range of operating pressures for liquid part(Varies with temperature)Silicone oil: from 2 kPa abs
Fluorine oil: from 54 kPa abs
Wetted materialSUS316 (diaphragm SUS316L), Alloy C-276 , Tantalum
Power17.9 to 45 V DC
Output signal4 to 20 mA DC (SFN communication)
4 to 20 mA DC (HART® communication)
Process connectionsRc 1/2 or 1/2 NPT internal thread or open to air
Flange boreFlush models: 80 mm, 50 mm, 40 mm. Protruding models: 100 mm, 80 mm, 50 mm

Product inquiry