Differential Pressure Transmitter / Pressure Transmitters Advanced Transmitter Model GTX_ _ _

In-line Gauge Pressure Transmitters

Model No.
GTX60G, GTX71G
GTX-G-In-line

This is a microprocessor-based smart transmitter with excellent stability. It can measure the pressure of gases, liquids, and steam, as well as liquid levels.

  • Safe instrumentation: IEC 61508-compliant and SIL2-certified
  • Excellent long-term stability: zero point drift of only ±0.1 % over 10 years
  • High-speed response within 100 ms for turbines and other applications that require fast response

Advanced Transmitter Gauge Pressure Transmitters (Model GTX_ _G) are used to measure the pressure of gases, liquids, and steam, as well as to measure tank pressure.
The use of directly mountable devices helps to cut installation and maintenance costs related to the impulse line and helps to keep equipment compact.
These transmitters achieve high accuracy of ±0.04 % and long-term reliability (zero drift of only ±0.1 % over 10 years), greatly reducing calibration work after installation.

ModelGTX60GGTX71G
Measurement span17.5~3500 kPa0.7~14 MPa
Setting range-100~3500 kPa-0.1~14 MPa
Reference accuracy±0.04%±0.15%
Fill fluidSilicone oil (general purpose models)
Waterproof and dust-proof constructionIEC IP67
Explosion-proof constructionKOSHA flameproof
FM explosion proof, intrinsic safe and Nonincendive
ATEX/NEPSI/IECEx flameproof, intrinsic safe and Type n
Wetted materialSUS316 (diaphragm SUS316L)
Power17.9~42V DC
Output signal4 to 20 mA DC (SFN communication)
4 to 20 mA DC (HART® communication)
Process connectionsMale: 1/2NPT, R1/2, G1/2, M20x1.5
Female: 1/2NPT, Rc1/2Male:1/2

Product inquiry