Azbil's electromagnetic flowmeters are high-performance flowmeters manufactured at the world's top-level flowmeter production and calibration facilities that have been registered under the ISO17025 Measurement Business Operator Registration System.
We provide a wide range of electromagnetic flowmeters to meet customer needs, including general type that can be used for a wide range of applications, 2-wire type that can reduce wiring costs, and other types such as submerged type, filling machine type, or water meter type that are specialized for various applications.
Electromagnetic Flowmeter MagneW™ PLUS+
Application
Suitable for measuring the flow rate of liquids with conductivity above a certain value, and can be used for a wide range of applications such as measuring industrial water and wastewater, as well as highly viscous fluids and slurry fluids.
2.5–1100 mm caliber lineup is available, which enables to support a wide flow range from a small to a large flow rate.
Example application:
Pulp and paper: pulp slurry, black liquor, green liquor, white liquor, white water, etc.
Food: milk, juice, beer, wine, yogurt, soy sauce, sauce, ketchup, jam, miso, etc.
Steel and metal: cooling water, drainage water, alumina slurry, lime slurry, corrosive fluid (hydrochloric acid, sulfuric acid, caustic soda, etc.), sea water, etc.
Chemistry: corrosive fluids (hydrochloric acid, sulfuric acid, caustic soda, etc.), highly viscous fluids, adhesive fluids, etc.
Equipment and machine: cooling water, brine, hot spring water, fire truck water discharge, etc.
Construction: cement slurry, earth and sand slurry, etc.
Features
- It is not affected by the temperature, pressure, density, or viscosity of the liquid.
- The detector face-to-face length can be adjusted according to Azbil Corporation standard or to the requirements of other companies.
- The data setting of the converter can be done by the infrared touch sensor, so there is no need to open the lid.
- Instantaneous%, instantaneous actual flow rate, and accumulated flow rate can be displayed simultaneously.
- Compact and lightweight.
- High accuracy of ± 0.5% of indicated value.
- It is possible to choose between the integrated type and the separated type, and it is also easy to change.
- The combination of model CFS100 Field Communication Software and model AZ-1SHM Smart HART modem enables remote parameter setting and modification as well as self-diagnosis.
Two-wire Electromagnetic Flowmeter MagneW™ PLUS+
Application
MagneW ™ Neo + 2-wire electromagnetic flowmeter does not require AC power supply and can be wired in 2-wire system, which can greatly reduce the cost of power supply and wiring. The development of an optimal excitation method has also realized the same functions and performance as conventional 4-wire electromagnetic flowmeters.
Can be used for flow monitoring, control, and accumulation of not only industrial water but also corrosive fluids and chemicals
Features
- From the field to the instrument room, it can be connected with 2-wire instrumentation, reducing the wiring cable and supplying power directly from DCS.
- It is not affected by the temperature, pressure, density, or viscosity of the liquid.
- There is no pressure loss.
- Explosion-proof type that can be used in explosive atmosphere is also available. (Exde [ia] IICT4)
- Instantaneous%, instantaneous actual flow rate, and accumulated flow display can be switched.
- Energy saving design with power consumption within 0.1W, 1/100 of the normal electromagnetic flow meter.
- High accuracy of ± 0.5% of indicated value.
- The combination of model CFS100 Field Communication Software and model AZ-1SHM Smart HART modem enables remote parameter setting and modification as well as self-diagnosis.
Submersible Electromagnetic Flowmeter MagneW ™ PLUS+ Model NNK_ _ _
Application
The submersible electromagnetic flowmeter is an electromagnetic flowmeter exclusively for open channels, which is listed in the electrical engineering handbook of the Japan Sewage Works Agency.
This system can measure flow rate with high accuracy in open channels such as tap water, sewage, industrial drainage, underdrains, and total volume control. And compared with other types of open channel flow meters, it does not require much maintenance.
The dummy detector can be used for a wide range of measurements, including large fluctuations in flow rates in summer and winter, and for large flow rates.
Features
- Ideal for measuring wastewater subject to total volume regulation.
- The body is made of hard vinyl chloride, so it can maintain corrosion resistance for a long period of time.
- By using dummy detectors, a wide range of flow rates can be measured.
- It is not affected by the temperature, pressure, density, or viscosity of the liquid.
- The data setting of the converter can be done by the infrared touch sensor, so there is no need to open the lid.
- Instantaneous%, instantaneous actual flow rate, and accumulated flow rate can be displayed simultaneously.
- The combination of model CFS100 Field Communication Software and model AZ-1SHM Smart HART modem enables remote parameter setting and modification as well as self-diagnosis.
Electromagnetic Flow Meter For Filling Machine MagneW™ Model MGR_ _ _
Application
Can be applied to flow measurement for PET, can, and pack filling equipment.
Ideal for measuring the filling flow of a wide range of beverages such as water, mineral water, soft drinks, carbonated drinks, Japanese sake, distilled spirits, wines, beers, etc.
Features
- High reproducibility can be achieved even for short time filling.
- Ideal for high-speed filling equipment for soft drinks, carbonated drinks, alcohol, etc.
- It has the performance and functions required for severe filling, such as high-speed response, high-speed sampling, and interference prevention mechanism.
- Detectors can be installed side by side with a minimum pitch of 94 mm.
- It is an integrated type that achieves compact installation.