You can download the installation file for the SLP-C7F for C7G firmware 1.x.x.
Please check the privacy policy at the bottom of this page, then fill in the customer information form to register and download the file.
Important Notice: To customers using HMI firmware ver. 5.0.4
Thank you for using the SLP-C7F.
A problem was found with the display unit (HMI) firmware ver. 5.0.4 that you installed using SLP-C7F. Please download the latest version of the SLP-C7F (ver. 2.3.1 or later) and update the HMI firmware to ver. 5.0.5.
Important Notice: To customers who have downloaded SLP-C7F ver. 1.5.0
Thank you for using the SLP-C7F.
A problem was found with SLP-C7F ver. 1.5.0 that was released on May 29, 2017. Please note that there are some restrictions on the PLC link settings.
File Information
| Device | Model C7G |
|---|---|
| Software | SLP-C7F |
| Version | 1.0.0 (Japanese) |
| Size | Approx. 5 MB |
| SLP-C7 | Icon | F/W Ver 1.x.x | F/W Ver 2.x.x~6.3.x |
|---|---|---|---|
| Ver 2.5.2 | Image
| × | ◎/○ |
| Ver 1.0.0 | Image
| ◎ | × |
◎◎: Read/write possible
○: Read/write possible (a firmware version mismatch message pops up when writing data)
Read: Parameters not available with the firmware are set to their default values.
Write: For parameters not available with the firmware, data is not written.
To edit data offline, read the settings from the controller.
SLP-C7F versions 2.5.4 and 1.0.0 can be installed on a single PC.
"The firmware version of the C7G" is the firmware version of its MAIN block.
You can confirm the version on the FIRMWARE VERSION screen on the C7G.
[SLP-C7F System Requirements]
| Item | Description | |
|---|---|---|
| Hardware | PC | Windows PC with an Intel CPU Recommended: Core i3–7 series, 1.5 GHz or faster (1 GHz min.) |
| Operating system for SLP-C7F ver. 1.5.0 or later | Japanese/English Windows 32-bit/64-bit Windows 7 SP1 or later Windows 8.1 or later (excluding RT), Windows 10 ver. 1909–20H2 Note: Operation on other Windows systems is not guaranteed. | |
| Operating system for SLP-C7F ver. 1.0.0 | Japanese Windows 32-bit/64-bit Windows 7 SP1 or later Windows 8.1 or later (excluding RT) Note: Operation on other Windows systems is not guaranteed. | |
| Memory | Recommended: 4 GB or more (2 GB min.) | |
| Hard disk drive | Recommended free space: 20 GB or more (10 GB min.) | |
| Display | 1366 x 768 resolution or higher, 32-bit color or higher is recommended | |
| Japanese input method | Windows-compatible Japanese IME | |
| PDF viewer | Adobe Acrobat Reader DC or later | |
| USB port | At least 1 port is required to connect to the C7G controller with a USB cable. | |
| Ethernet port | At least 1 port is required to connect to the C7G controller via Ethernet. | |
| MicroUSB cable | Micro-USB to USB cable*1 | |
| Mouse | Required | |
| Keyboard | Required | |
| Other | *1. Azbil's USB loader cable (model No. 81441177-001) cannot be used because it is a Mini-USB cable. Use a commercially available Micro-USB data cable. (A charge-only Micro-USB cable cannot be used.) | |
The following text is machine translated. Please be aware of this in advance.
*****************************************************************************
SLP-C7 Change Log
Update History (Japanese/English Version)
Version: 2.5.4
Supported Firmware Versions: 2.x.x to 6.3.x
Configuration File Extensions: c7g5/c7g5x
Support Start: February 2023
Version: 2.5.2
Supported Firmware Versions: 2.x.x to 6.3.x
Configuration File Extensions: c7g5/c7g5x
Support Start: October 2021
Version: 2.5.1
Supported Firmware Versions: 2.x.x to 6.3.x
Configuration File Extensions: c7g5/c7g5x
Support Start: August 2021
Version: 2.5.0
Supported Firmware Versions: 2.x.x to 6.3.x
Configuration File Extensions: c7g5/c7g5x
Support Start: May 2021
Version: 2.4.0
Supported Firmware Versions: 2.x.x to 6.2.x
Configuration File Extensions: c7g5/c7g5x
Support Start: January 2020
Version: 2.3.0 to 2.3.1
Supported Firmware Versions: 2.x.x to 6.1.x
Configuration File Extensions: c7g4
Support Start: May 2019
Changes:
・Added settings for loop types 12, 22, 23
・Added Keyence KV to the connected PLC in the PLC link
・Support for display firmware update (2.3.1)
Version: 2.2.0
Supported Firmware Versions: 2.x.x to 6.1.x
Configuration File Extensions: c7g4
Support Start: February 2019
Changes:
・Added support for Chinese language selection
Version: 2.1.0
Supported Firmware Versions: 2.x.x to 6.x.x
Configuration File Extensions: c7g4
Support Start: October 2018
Changes:
・Changed main menu button
・Added graph display to the [Health Index] screen (paid version)
Version: 2.0.0
Supported Firmware Versions: 2.x.x to 6.x.x
Configuration File Extensions: c7g4
Support Start: August 2018
Changes:
・Changed main menu button
・Added pattern operation settings
・Added display firmware update function
Version 1.6.0
Supported Firmware Versions: 2.x.x to 5.x.x
Configuration File Extensions: c7g4
Support Start: August 2017
Changes:
・Support for hiding unnecessary setting items
・Added logical operation screen
・Added line graph table
Version: 1.5.0 to 1.5.1
Supported Firmware Versions: 2.x.x to 4.x.x
Configuration File Extensions: c7g4
Support Start: June 2017
Changes:
・Support for reading setting files from previous versions (extensions c7g2, c7g3)
Version: 1.3.0 to 1.3.2
Supported Firmware Versions: 2.x.x to 3.x.x
Configuration File Extensions: c7g3
Support Start: December 2016, January 2017
Changes:
・Added support for PLCLink
Version: 1.2.0
Supported Firmware Versions: 2.x.x
Configuration File Extensions: c7g2
Support Start: September 2016
Changes:
・Support for Windows 10
Version: 1.0.0
Supported Firmware Versions: 1.x.x
Configuration File Extensions: c7g
Support Start: June 2016
*****************************************************************************
Azbil Corporation
*****************************************************************************