Electromagnetic Flowmeters

Electromagnetic Flowmeter MagneW™ PLUS+ Model MGG_ _ _/MGF_ _ _/MGS_ _ _

Model No.
MGG14C, MGG17D, MGG17F, MGG18D, MGG18F, MGG18U, MGG19D, MGG19F, MGS28U
MGG

With versatile functions, high visibility and environmental resistance, the MagneW™ PLUS+ electromagnetic flowmeter has a wide range of applications for cold and hot water, slurry, chemicals, and corrosive liquids.

  • Reliable flow rate output even for corrosive liquids and slurries
  • Mirror-finish PFA liner minimizes maintenance necessity
  • The same face-to-face dimension as Azbil's conventional flowmeters and third-party products makes it replaceable.
  • A great selection of models (explosion-proof, sanitary, models with flow switch function, etc.) for a wide range of applications

Catalogs

Specification Sheets

User's Manuals

Loader Packages, Drivers

Device DTM

Device DTM-HART®

Model NameTypeS/W VersionVersion
PTG_ _ _<Rev1>Pressure Transmitter>=E.22.4.19.116 and
Extension 2.0.0.0 for Model AVP7_ _ *1
ATT_ _ _<Rev1>Temperature Transmitter>=1.4
MGG_ _ _<Rev1>Flow Meter>=6.0
MTG_ _ _<Rev2>Flow Meter>=7.0
AVP70_<Rev1>Valve Positioner>=2.2
AVP77_, AVP78_, AVP79_<Rev1>Valve Positioner>=2.2
Advanced Transmitter<Rev2>Pressure Transmitter>=5.1
Pro-V<Rev6> *2(Ax2_ _ _)Flow Meter>=78.02

*1. Please install the extension to use the step response test and valve signature functions of models AVP7 _ _.

*2. Models AX2 _ _ _ are registered as “Pro-V” by the FieldComm Group. Devices with a software version ending with 78.02 or greater are supported. The software version is displayed at power-on.

Device DTM-FOUNDATION™ Fieldbus

Model NameTypeS/W VersionVersion
MGG_ _ _<Rev1>Flow Meter>=2.22.6.15.75 and
Extension 2.0.0.0 for Model AVP7_ _ *3
AVP70_ <Rev1>Valve Positioner>=2.6
GTX_ _ _ <Rev1>Pressure Transmitter>=1.5

*3. Please install the extension in order to use the step response test and valve signature functions of models AVP7 _ _.

DD

DD-HART®

Model NameTypeDevice TypeDevice revisionDD Revision
MGG_ _ _Electromagnetic Flowmeter00010102
MGG_ _ _Electromagnetic Flowmeter000c0102

DD-FOUNDATION™ Fieldbus

Model NameTypeDevice TypeDevice revisionDD Revision
MGG_ _ _Electromagnetic Flowmeter16010103

Product inquiry