Electromagnetic Flowmeters

Two-wire Electromagnetic Flowmeter MagneW™ Two-wire PLUS+ Model MTG_ _ _

Model No.
MTG14C, MTG18A, MTG18B
MTG15

This electromagnetic flowmeter allows the creation of a two-wire system between the instrument room and the field. It can be replaced with various two-wire flowmeters. In addition, it uses much less energy than four-wire electromagnetic flowmeters.

  • Noise resistance has improved up to 700 % (on average, 250 %) over our conventional two-wire electromagnetic flowmeters.
  • Allows the creation of a two-wire system between the field and the instrument room, reducing instrumentation and wiring costs.
  • 4–20m A DC output with two-wire instrumentation. Pulse output can also be used by adding or changing wiring.
  • Explosion-proof models are available. The face-to-face dimension is compatible with our conventional two-wire electromagnetic flowmeters, making replacement possible.

The MagneW™ Two-wire PLUS+ the successor to model SMT_ _ _, which was the first of its kind in the world. It is the world's most widely used two-wire electromagnetic flowmeter.
With its patented method of direct current excitation and variable excitation current, power consumption is reduced without compromising the high level of performance. Available in integrated and a remote types, this flowmeter can be used in a wide range of settings, including explosion-proof and outdoor environments.

Two-wire operation raises performance and lowers installation costs.

Far greater performance than the previous two-wire electromagnetic flowmeter, with capabilities equivalent to a four-wire electromagnetic flowmeter (except for use with slurries).
Because it runs on two-wire 24 V DC, it can use the same wiring as instruments such as pressure and temperature gauges, and it can run off of a direct supply from a DCS as well.

Eco-friendly design

Friendly to the environment because it helps to save energy, this flowmeter uses less than 1/100 the power of a four-wire electromagnetic flowmeter.

Compatible with HART® and Model CFS100 communicators as a standard feature.

Communication with Model CFS100 is supported as in previous models. Communication superimposed on an analog signal can be used by selecting the HART® communicator function.

Product inquiry