You can download the installation (upgrade) file for the MLP-F4Q.
Please check the privacy policy at the bottom of this page, then fill in the customer information form to register and download the file.
File Information
| Device | Model F4Q |
|---|---|
| Software | MLP-F4Q |
| Version | 4.0.4 |
| Size | Approx. 7.6 MB |
[System Requirements]
| Item | Description | |
|---|---|---|
| Hardware | PC | A PC that can run Windows 10 or Windows 11 OS Recommended: 1.5 GHz or faster processor (1 GHz min.) |
| Operating system *1 | 64-bit Windows 10 (English/Japanese, version 1903 or later) Windows 11 (English/Japanese) | |
| Memory | Recommended: 4 GB or more (2 GB min.) | |
| Hard disk drive | Recommended free space: 20 GB or more (10 GB min.) | |
| Display | 1366 x 768 resolution or higher, 32-bit color or higher is recommended | |
| Keyboard | Required | |
| Pointing device | Windows-compatible mouse or the equivalent | |
| USB port *2 | At least 1 port is required to connect to the F4Q | |
| Software | Adobe Acrobat Reader DC or later This is required to view the user's manual (PDF). If the software is not installed on your PC, download and install it from the Adobe web page. | |
*1. Operation on other systems is not guaranteed.
Please perform a Windows Update and keep Windows up to date.
*2. The USB port on the main unit is a micro USB Type-B. Please use a standard USB 2.0 cable for connection.
*****************************************************************************
Ver4.0.4 (2026-04)
Added upper and lower limit range restrictions for parameter settings that depend on full-scale flow rate.
Added range restrictions for SP settings.
Added new parameters:
Driver enable time upon completion of reception (C45)
Control Response Setting 2
Added "Flow rate zero point adjustment clear" to device operations.
Added a feature to export parameter settings in CSV format.
Added a consistency check for certain parameters during “Write parameters to the device” and “Save” operations.
Others
Ver3.0.0 (2025-03)
A flow rate range added (model F4Q0500 supported)
Others
Ver2.0.2 (2024-05)
Supported Windows 11
Ver2.0.2 (2022-09)
A flow rate range added (F4Q0050J, F4Q0050K, F4Q0100, F4Q0200)
Parameter for F4Q Added (Delay time to detect hardware anomalies)
Others
Ver1.0.5 (2021-09)
Initial version
*****************************************************************************
Azbil Corporation
*************************************************************************
- Consent to the Privacy Policy for the Protection of Personal Information
Please read the “Privacy Policy for the Protection of Personal Information,” and if you agree to its terms, check the box labeled “I agree to the collection of personal information.”
Fill in the displayed “Request Document Form,” then click the “Submit” button. - Consent to the Software License Agreement
Please read the “Software License Agreement,” and if you agree, click “I agree to the terms and conditions and would like to download the software.” The download will begin automatically. - Double-click "setup_MLPF4Q_V_□_□_□.msi"*3 to start installation of the MLP-F4Q.
- For the rest of the procedure, refer to section 1-3, "Installation" of the user's manual (document No. CP-SP-1457E).
*3. □ represents a number. Example: setup_MLPF4Q_V_3_0_0.msi